313-3 Industrial Use Regulations
MB: Business Park |
|
---|---|
Use Type |
Principal Permitted Use |
Civic Use Types |
Minor Utilities Administrative |
Commercial Use Types |
Warehousing, Storage and Distribution Office and Professional Service |
Industrial Use Types* |
Research/Light Industrial |
Use Type |
Conditionally Permitted Use |
Commercial Use Types |
Retail Sales Retail Service Uses Transient Habitation |
Use Types Not Listed in This Table** |
Any use not specifically enumerated in this Division, if it is similar to and compatible with the uses permitted in the MB zone. |
Development Standards |
|
Minimum Lot Size |
10,000 square feet. |
Minimum Lot Width |
Sixty feet (60') |
Maximum Lot Depth |
(None specified.) |
Maximum Density |
(None specified.) |
Minimum Yard Setbacks*** |
|
Front |
Thirty feet (30'). |
Rear |
Ten feet (10') |
Side |
Thirty feet (30') where side yard adjoins a public street and ten feet (10') otherwise |
Flag Lots |
For Flag Lots, the Director, in consultation with the Public Works Department, shall establish the minimum yard that is required for a vehicular turnaround on the lot. |
Maximum Ground Coverage |
Fifty percent (50%). |
Maximum Structure Height |
Fifty feet (50'). |
Permitted Main Building Types |
Nonresidential Detached, Attached or Multiple/Group Limited Mixed Residential and Nonresidential |
*See, Industrial Performance Standards, Section 313-103.1.
**See, “Classifying Uses Not Specifically Mentioned in Use Type Descriptions,” Section 313-165.
*** Note: Setbacks may be modified by other provisions of this Code or State law. For example, see Section 313-30: “Alquist-Priolo Fault Hazard” and the “Fire Safe Regulations” at Title III, Division 11.
(Former Section CZ#A313-25(A-C))
ML: Light Industrial |
|
---|---|
Use Type |
Principal Permitted Use |
Civic Use Types |
Minor Utilities |
Commercial Use Types |
Warehousing, Storage and Distribution |
Heavy Commercial |
|
Industrial Use Types* |
Research/Light Industrial Aquaculture; subject to the Coastal-Dependent Industrial Development Regulations |
Use Type |
Conditionally Permitted Use |
Residential Use Types |
Caretaker’s Residence |
Civic Use Types |
Oil and Gas Pipelines; subject to the Oil and Gas Pipeline Regulations Major Electrical Distribution Lines; subject to the Major Electrical Distribution Lines Regulations Minor Generation and Distribution Facilities Extensive Impact Civic Uses |
Commercial Use Types |
Retail Service Retail Sales |
Industrial Use Types* |
Coastal-Dependent; subject to the Coastal-Dependent Industrial Development Regulations Coastal-Related; subject to the Coastal-Dependent Industrial Development Regulations Timber Product Processing |
Agricultural Use Type |
General Agriculture |
Extractive Use Type |
Surface Mining - 2; subject to the Surface Mining Regulations |
Natural Resource Use Type |
Coastal Access Facilities |
Use Types Not Listed in This Table** |
Any use not specifically enumerated in this Division, if it is similar to and compatible with the uses permitted in the ML zone. |
Development Standards |
|
Minimum Lot Size |
10,000 square feet. |
Minimum Lot Width |
Sixty feet (60') |
Maximum Lot Depth |
(None specified.) |
Maximum Density |
(None specified.) |
Minimum Yard Setbacks*** |
|
Front |
Twenty-five feet (25'). |
Rear |
Twenty-five feet (25'). |
Side |
Twenty-five feet (25') on one side, and zero feet (0') on one side. |
Flag Lots |
For Flag Lots, the Director, in consultation with the Public Works Department, shall establish the minimum yard that is required for a vehicular turnaround on the lot. |
Maximum Ground Coverage |
(None specified.) |
Maximum Structure Height |
Fifty feet (50'). |
Permitted Main Building Types |
Ancillary Residential; Manufactured Home. Unlimited Mixed Residential - Nonresidential. Nonresidential Detached or Multiple/Group. |
*See, Industrial Performance Standards, Section 313-103.1.
**See, “Classifying Uses Not Specifically Mentioned in Use Type Descriptions,” Section 313-165.
*** Note: Setbacks may be modified by other provisions of this Code or State law. For example, see Section 313-30: “Alquist-Priolo Fault Hazard” and the “Fire Safe Regulations” at Title III, Division 11.
(Former Section CZ#A313-26(A-C))
MG: Industrial General |
|
---|---|
Use Type |
Principal Permitted Use |
Civic Use Types |
Minor Utilities |
Commercial Use Types |
Warehousing, Storage and Distribution Heavy Commercial |
Industrial Use Types* |
Research/Light Industrial Aquaculture; subject to the Coastal-Dependent Industrial Development Regulations Timber Product Processing |
Use Type |
Conditionally Permitted Use |
Residential Use Types |
Caretaker’s Residence |
Civic Use Types |
Solid Waste Disposal; subject to the Solid Waste Disposal Regulations Oil and Gas Pipelines; subject to the Oil and Gas Pipelines Regulations Minor Generation and Distribution Facilities Extensive Impact Civic Uses Major Electrical Distribution Lines; subject to the Electrical Distribution Lines Regulations |
Industrial Use Type* |
Heavy Industrial Hazardous Industrial Coastal-Dependent; subject to the Coastal-Dependent Industrial Development Regulations Coastal-Related; subject to the Coastal-Dependent Industrial Development Regulations |
Agricultural Use Type |
General Agriculture |
Extractive Use Type |
Surface Mining - 1; subject to the Surface Mining Regulations Surface Mining - 2; subject to the Surface Mining Regulations Oil and Gas Drilling and Processing; subject to the Oil and Gas Drilling and Processing Regulations Metallic Mineral Extraction; subject to the Surface Mining Regulations |
Natural Resource Use Type |
Coastal Access Facilities |
Use Types Not Listed in This Table** |
Any use not specifically enumerated in this Division, if it is similar to and compatible with the uses permitted in the MG zone. |
*See, Industrial Performance Standards, Section 313-103.1.
**See, “Classifying Uses Not Specifically Mentioned in Use Type Descriptions,” Section 313-165.
MG: Industrial General |
|
---|---|
Development Standards |
|
Minimum Lot Size |
One acre (1a). |
Minimum Lot Width |
(None specified.) |
Maximum Lot Depth |
(None specified.) |
Maximum Density |
(None specified.) |
Minimum Yard Setbacks*** |
|
Front |
Fifty feet (50'). |
Rear |
Fifty feet (50'). |
Side |
Twenty-five feet (25'). |
Flag Lots |
For Flag Lots, the Director, in consultation with the Public Works Department, shall establish the minimum yard that is required for a vehicular turnaround on the lot. |
Maximum Ground Coverage |
(None specified.) |
Maximum Structure Height |
Fifty feet (50') plus one foot (1') for each foot of front yard setback over fifty feet (50') to a maximum of seventy-five feet (75'). |
Permitted Main Building Types |
Ancillary Residential; Manufactured Home. Unlimited Mixed Residential - Nonresidential. Nonresidential Detached or Multiple/Group. |
*** Note: Setbacks may be modified by other provisions of this Code or State law. For example, see Section 313-30: “Alquist-Priolo Fault Hazard” and the “Fire Safe Regulations” at Title III, Division 11.
(Former Section CZ#A313-27(A-C))
MC: Industrial/Coastal-Dependent |
|
---|---|
Use Type |
Principal Permitted Use |
Civic Use Types |
Minor Utilities |
Industrial Use Types* |
Coastal-Dependent; subject to the Coastal-Dependent Industrial Development Regulations Aquaculture; subject to the Coastal-Dependent Industrial Regulations |
Use Type |
Conditionally Permitted Use |
Residential Use Types |
Caretaker’s Residence |
Civic Use Types |
Solid Waste Disposal; subject to the Solid Waste Disposal Regulations Oil and Gas Pipelines; subject to the Oil and Gas Pipelines Regulations Major Electrical Distribution Lines; subject to the Electrical Distribution Lines Regulations |
Commercial Use Types |
Coastal-Dependent Recreation |
Industrial Use Type* |
Coastal-Related; subject to the Coastal-Dependent Industrial Regulations Heavy Industrial, limited to alteration, improvement, and relocation of existing facilities |
Extractive Use Type |
Surface Mining - 1; subject to Surface Mining Regulations Surface Mining - 2; subject to Surface Mining Regulations Oil and Gas Drilling Processing; subject to Oil and Gas Drilling and Processing Regulations |
Natural Resource Use Type |
Coastal Access Facilities |
Use Type |
Interim Conditionally Permitted Use |
Certain uses Principally and Conditionally permitted in Section 313-3.2 ML: Light Industrial and Section 313-3.3 MG: Industrial General not listed above; subject to the Interim Uses in the Coastal-Dependent Industrial Zone Performance Standards contained in Section 313-104.1. Pursuant to Section 313-104.1, certain uses included in the following use types would not be allowed due to their inability to be removed or relocated in a feasible manner. |
|
Civic Use Types |
Extensive Impact Civic Uses Minor Generation and Distribution Facilities |
Commercial Use Types |
Heavy Commercial Retail Sales Retail Service Warehousing, Storage and Distribution |
Industrial Use Types |
Heavy Industrial Research/Light Industrial Timber Product Processing |
Agricultural Use Type |
General Agriculture |
Use Types Not Listed in This Table** |
Any use not specifically enumerated in this Division, if it is similar to and compatible with the uses, excepting Interim Conditionally Permitted Uses, permitted in the MC zone. |
*See, Industrial Performance Standards, Section 313-103.1.
**See, “Classifying Uses Not Specifically Mentioned in Use Type Descriptions,” Section 313-165.
MC: Industrial/Coastal-Dependent |
|
---|---|
Development Standards |
|
Minimum Lot Size |
10,000 square feet. |
Minimum Lot Width |
(None specified.) |
Maximum Lot Depth |
(None specified.) |
Maximum Density |
(None specified.) |
Minimum Yard Setbacks*** |
|
Front |
Front yard setbacks in the MC zone district shall be as designated by the Development Standard Combining Zone regulations. |
Rear |
Rear yard setbacks in the MC zone district shall be as designated by the Development Standard Combining Zone regulations. |
Side |
Side yard setbacks in the MC zone district shall be as designated by the Development Standard Combining Zone regulations. |
Exceptions to Required Rear or Side Yard Setbacks |
Where a required side or rear yard abuts the ocean or harbor, and is proposed to be developed for a coastal-dependent use, an exception to the required side or rear yard may be granted through a Special Permit. |
Flag Lots |
For Flag Lots, the Director, in consultation with the Public Works Department, shall establish the minimum yard that is required for a vehicular turnaround on the lot. |
Maximum Ground Coverage |
(None specified.) |
Maximum Structure Height |
Fifty feet (50') plus one foot (1') for each foot of front yard setback over fifty feet (50') to a maximum of seventy-five feet (75'). |
Permitted Main Building Types |
Ancillary Residential; Manufactured Home. Unlimited Mixed Residential-Nonresidential. Nonresidential Detached or Multiple/Group. |
*** Note: Setbacks may be modified by other provisions of this Code or State law. For example, see Section 313-30: “Alquist-Priolo Fault Hazard” and the “Fire Safe Regulations” at Title III, Division 11.
(Former Section CZ#A313-28(A-C))