313-4 Public Use Zones
PF1: Public Facility (Urban) |
|
---|---|
Use Type |
Principal Permitted Use |
Civic Use Types |
Essential Services |
Administrative |
|
Community Assembly |
|
Non-Assembly Cultural |
|
Public Recreation and Open Space |
|
Health Care Services |
|
Minor Utilities |
|
Use Type |
Conditionally Permitted Use |
Residential Use Types |
Caretaker’s Residence |
Civic Use Types |
Extensive Impact Civic Uses |
Oil and Gas Pipelines; subject to the Oil and Gas Pipelines Regulations |
|
Major Electrical Distribution Lines; subject to the Electrical Distribution Lines Regulations |
|
Minor Generation and Distribution Facilities |
|
Natural Resource Use Type |
Coastal Access Facilities |
Use Types Not Listed in This Table** |
Any use not specifically enumerated in this Division, if it is similar to and compatible with the uses permitted in the PF1 zone. |
Development Standards |
|
Minimum Lot Size |
5,000 square feet |
Minimum Lot Width |
Fifty feet (50'). |
Maximum Lot Depth |
Three (3) times the lot width. |
Maximum Density |
(None specified.) |
Minimum Yard Setbacks*** |
|
Front |
None, except that where frontage is in a block which is partially in a Residential (RS, R2, RM) zone, the front yard shall be same as that required in such Residential zone |
Rear |
Fifteen feet (15'), except that where a rear yard abuts an alley, such rear yard may be not less than five feet (5'). |
Side |
None, except that a side yard of an interior lot abutting on a Residential (RS, R2, RM) zone or an Agricultural (AE) zone shall not be less than the front yard required in such Residential zone or Agricultural zone. |
Flag Lots |
For Flag Lots, the Director, in consultation with the Public Works Department, shall establish the minimum yard that is required for a vehicular turnaround on the lot. |
Maximum Ground Coverage |
(None specified.) |
Maximum Structure Height |
Forty-five feet (45'). |
Permitted Main Building Types |
Ancillary Residential; Manufactured Home. |
Limited Mixed Residential - Nonresidential. Nonresidential Detached, Multiple/Group. |
**See, “Classifying Uses Not Specifically Mentioned in Use Type Descriptions,” Section 313-165.
*** Note: Setbacks may be modified by other provisions of this Code or State law. For example, see Section 313-30: “Alquist-Priolo Fault Hazard” and the “Fire Safe Regulations” at Title III, Division 11.
(Former Section CZ#A313-18(A-C); Amended by Ord. 1842, Sec. 19, 8/16/88)
PF2: Public Facility (Rural) |
|
---|---|
Use Type |
Principal Permitted Use |
Civic Use Types |
Essential Services Community Assembly Public Recreation and Open Spaces Minor Utilities |
Use Type |
Conditionally Permitted Use |
Residential Use Types |
Caretaker’s Residence |
Civic Use Types |
Extensive Impact Civic Uses Solid Waste Disposal; subject to the Solid Waste and Dredge Spoils Disposal Regulations Oil and Gas Pipelines; subject to the Oil and Gas Pipelines Regulations Major Electrical Distribution Lines; subject to the Electrical Transmission Lines Regulations |
Minor Generation and Distribution Facilities |
|
Natural Resource Use Type |
Coastal Access Facilities |
Use Types Not Listed in This Table** |
Any use not specifically enumerated in this Division, if it is similar to and compatible with the uses permitted in the PF2 zone. |
Development Standards |
|
Minimum Lot Size |
5,000 square feet |
Minimum Lot Width |
Fifty feet (50'). |
Maximum Lot Depth |
Three (3) times the lot width. |
Maximum Density |
(None specified.) |
Minimum Yard Setbacks*** |
|
Front |
None, except that where frontage is in a block which is partially in a Residential (RS, R2, RM) zone, the front yard shall be same as that required in such Residential zone |
Rear |
Fifteen feet (15'), except that where a rear yard abuts an alley, such rear yard may be not less than five feet (5'). |
Side |
None, except that a side yard of an interior lot abutting on a Residential (RS, R2, RM) zone or an Agricultural (AE) zone shall not be less than the front yard required in such Residential zone or Agricultural zone. |
Flag Lots |
For Flag Lots, the Director, in consultation with the Public Works Department, shall establish the minimum yard that is required for a vehicular turnaround on the lot. |
Maximum Ground Coverage |
Thirty-five percent (35%). |
Maximum Structure Height |
Forty-five feet (45'). |
Permitted Main Building Types |
Ancillary Residential; Manufactured Home. Limited Mixed Residential - Nonresidential. Nonresidential Detached, Multiple/Group. |
**See, “Classifying Uses Not Specifically Mentioned in Use Type Descriptions,” Section 313-165.
*** Note: Setbacks may be modified by other provisions of this Code or State law. For example, see Section 313-30: “Alquist-Priolo Fault Hazard” and the “Fire Safe Regulations” at Title III, Division 11.